Fujitronic Programmable Operation Display UG520H-x Instrukcja Użytkownika Strona 108

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 275
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 107
2 - 39
13 OMRON PLC 1
<E.g.> EM0:30000
Bank No.
Address No.
Colon
Available Memory
*
1When using EMn (extensional data memory), specify the bank
number (CV: 0 to 7, CS1: 0 to C).
The assigned memory is indicated while editing the screen as
illustrated:
Set the memory to the extent of the memory range of each PLC model.
Use TYPE number to assign indirect memory for macro programs.
CV
Memory TYPE Remarks
DM (data memory) 0
CH (input/output relay) 1
AR (alarm relay) 4
T (timer/current value) 5
C(counter/current value) 6
EMn (extensional data memory) 7 *1
TU (timer/contact) 9 Read only
CU (counter/contact) 10 Read only
CS1
Memory TYPE Remarks
DM (data memory) 0
CH (input/output relay) 1
H(holding relay) 2
A (alarm relay) 4
T (timer/current value) 5
C(counter/current value) 6
EMn (extensional data memory) 7
*
1
W (Internal Relay) 8
TU (timer/contact) 9 Read only
CU (counter/contact) 10 Read only
C
Memory TYPE Remarks
DM (data memory) 0
CH (input/output relay) 1
HR (holding relay) 2
LR (latch relay) 3
AR (alarm relay) 4
T (timer/current value) 5
C(counter/current value) 6
EMn (extensional data memory) 7 *1
TU (timer/contact) 9 Read only
CU (counter/contact) 10 Read only
Przeglądanie stron 107
1 2 ... 103 104 105 106 107 108 109 110 111 112 113 ... 274 275

Komentarze do niniejszej Instrukcji

Brak uwag